Pepperl+Fuchs Surge Protection Barrier

Katalogda Pepperl+Fuchs markasının Surge Protection Barrier grubunda 61 kalem bulunuyor. Aşağıda parça kodları, ürünün kendi teknik verisinden gelen özellikler ve seri sayfalarına bağlantılar var.

Teklif: +90 533 461 51 10

Teknik karşılaştırma

Parça koduDegree of protectionAmbient temperatureConnectionNominal voltage
FN-LB-IIEC 60529:2001-30 ... 60 °C (-22 ... 140 °F) For usage in hazardous area observe the EC-type examination certificate.——
FP-LB-IIEC 60529:2001-30 ... 60 °C (-22 ... 140 °F) For usage in hazardous area observe the EC-type examination certificate.——
FS-LB-IIEC 60529:2001-30 ... 60 °C (-22 ... 140 °F) For usage in hazardous area observe the EC-type examination certificate.——
M-LB-1.150.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 120 V AC, 50 ... 60 Hz
M-LB-1.275.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 230 V AC, 50 ... 60 Hz
M-LB-2.150.T3.DIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 120 V AC, 50 ... 60 Hz
M-LB-2.150TN.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 120 V AC, 50 ... 60 Hz
M-LB-2.255.T3.DIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 230 V AC, 50 ... 60 Hz
M-LB-2.275TN.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 230 V AC, 50 ... 60 Hz
M-LB-2.275TT.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 230 V AC, 50 ... 60 Hz
M-LB-2.30.T3.DIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 24 V AC, 50 ... 60 Hz
M-LB-2112IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 1 V DC
M-LB-2112.SPIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 1 V DC
M-LB-2114IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 1 V DC
M-LB-2114.SPIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 1 V DC
M-LB-2142IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 24 V DC
M-LB-2142.SPIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 24 V DC
M-LB-2144IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 24 V DC
M-LB-2144.SPIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 24 V DC
M-LB-2615IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5, 6 unprotected area: terminals 1, 2, 3U N 1 V DC
M-LB-2616IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5, 6 unprotected area: terminals 1, 2, 3U N 1 V DC
M-LB-2645IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5, 6 unprotected area: terminals 1, 2, 3U N 24 V DC
M-LB-2646IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5, 6 unprotected area: terminals 1, 2, 3U N 24 V DC
M-LB-3.150TNC.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 120 V AC, 50 ... 60 Hz 240 V AC, 50 ... 60 Hz
M-LB-3.275TNC.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 230 V AC, 50 ... 60 Hz 400 V AC, 50 ... 60 Hz
M-LB-4.150TNS.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 120 V AC, 50 ... 60 Hz 240 V AC, 50 ... 60 Hz
M-LB-4.275TNS.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 230 V AC, 50 ... 60 Hz 400 V AC, 50 ... 60 Hz
M-LB-4.275TT.DIEC 60529-40 ... 80 °C (-40 ... 176 °F)terminals 11, 12, 14U N 230 V AC, 50 ... 60 Hz 400 V AC, 50 ... 60 Hz
M-LB-4212IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 5 V
M-LB-4214IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 5 V
M-LB-4222IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 12 V
M-LB-4224IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 12 V
M-LB-4242IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 24 V
M-LB-4244IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 24 V
M-LB-4252IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 48 V
M-LB-4254IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 48 V
M-LB-4272IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 180 V
M-LB-4282IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F)protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 230 V
M-LB-Ex-2112IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 1 V DC
M-LB-Ex-2112.SPIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 1 V DC
M-LB-Ex-2114IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 1 V DC
M-LB-Ex-2114.SPIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 1 V DC
M-LB-Ex-2142IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 24 V DC
M-LB-Ex-2142.SPIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 24 V DC
M-LB-Ex-2144IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 24 V DC
M-LB-Ex-2144.SPIEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5 unprotected area: terminals 2, 3 shielding/grounding: terminal 1 (optional)U N 24 V DC
M-LB-Ex-2615IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5, 6 unprotected area: terminals 1, 2, 3U N 1 V DC
M-LB-Ex-2616IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5, 6 unprotected area: terminals 1, 2, 3U N 1 V DC
M-LB-Ex-2645IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5, 6 unprotected area: terminals 1, 2, 3U N 24 V DC
M-LB-Ex-2646IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating.protected area: terminals 4, 5, 6 unprotected area: terminals 1, 2, 3U N 24 V DC
M-LB-Ex-4242IEC 60529:2013-40 ... 80 °C (-40 ... 176 °F) For usage in hazardous area observe the EU-type examination certificate.protected area: terminals 1', 2' unprotected area: terminals 1, 2U N 24 V
P-LB-1.A.13IEC 60529:2001-20 ... 60 °C (-4 ... 140 °F)terminals 1, 3—
P-LB-1.B.12IEC 60529:2001-20 ... 60 °C (-4 ... 140 °F)terminals 1, 2—
P-LB-1.C.123IEC 60529:2001-20 ... 60 °C (-4 ... 140 °F)terminals 1, 2, 3—
P-LB-1.D.1234IEC 60529:2001-20 ... 60 °C (-4 ... 140 °F)terminals 1, 2, 3, 4—
P-LB-1.E.23IEC 60529:2001-20 ... 60 °C (-4 ... 140 °F)terminals 2, 3—
P-LB-1.F.1236IEC 60529:2001-20 ... 60 °C (-4 ... 140 °F)terminals 1, 2, 3, 6—
P-LB-2.A.1346IEC 60529:2001-20 ... 60 °C (-4 ... 140 °F)terminals 1, 3; 4, 6—
P-LB-2.B.1245IEC 60529:2001-20 ... 60 °C (-4 ... 140 °F)terminals 1, 2; 4, 5—
P-LB-2.C.2356IEC 60529:2001-20 ... 60 °C (-4 ... 140 °F)Terminals 2, 3; 5, 6—

Toplam 61 kalemin ilk 60 tanesi gösteriliyor. Surge Protection Barrier kategorisinin tamamı ve Pepperl+Fuchs marka sayfası.

Sık sorulanlar

Pepperl+Fuchs Surge Protection Barrier kategorisinde kaç model var?
Kataloğumuzda Pepperl+Fuchs markasının "Surge Protection Barrier" grubunda 61 kalem listelenir.
Pepperl+Fuchs Surge Protection Barrier için teklif nasıl alınır?
Parça kodunu +90 533 461 51 10 numarasından ya da iletişim formundan iletmeniz yeterli. Fiyat sitede yayınlanmaz; her talep için teklif hazırlanır.
WhatsApp’tan yazın