LGC2 Level probe

Level probe

Equipment architecture
As standard, the complete measuring system consists of a level probe and a transmitter power supply unit with a supply voltage of 10.5 to 30 V DC.
Construction type
device with rod probe
Series
LGC2
Rated voltage
U r level probe and Pt100 (optional): - 10.5 ... 35 V DC (non-hazardous area) - 10.5 ... 30 V DC (hazardous area) temperature head transmitter (optional): 8 ... 35 V DC
Current consumption
level probe and Pt100 (optional): max. ≤ 23 mA, min. ≥ 3.6 mA temperature head transmitter (optional): max. ≤ 25 mA, min. ≥ 3.5 mA
Tüm teknik özellikler (24)

Teknik Özellikler

Teknik Veriler

Equipment architecture
As standard, the complete measuring system consists of a level probe and a transmitter power supply unit with a supply voltage of 10.5 to 30 V DC.
Construction type
device with rod probe
Series
LGC2
Rated voltage
U r level probe and Pt100 (optional): - 10.5 ... 35 V DC (non-hazardous area) - 10.5 ... 30 V DC (hazardous area) temperature head transmitter (optional): 8 ... 35 V DC
Current consumption
level probe and Pt100 (optional): max. ≤ 23 mA, min. ≥ 3.6 mA temperature head transmitter (optional): max. ≤ 25 mA, min. ≥ 3.5 mA
Power consumption
level probe and Pt100 (optional): - ≤ 0.805 W at 35 V DC (non-hazardous area) - ≤ 0.690 W at 30 V DC (hazardous area) temperature head transmitter (optional): ≤ 0.875 W at 35 V DC
Reverse polarity protection
Reverse voltage protection is integrated in the level probe and in the temperature head transmitter changing the polarities has no impact on operation.
Residual ripple
level probe and Pt100 (optional): No impact on the 4 to 20 mA signal up to ±5 % residual ripple within the permitted voltage range. temperature head transmitter (optional): U ss ≥ 5 V at U ≥ 13 V, f max. = 1 kHz
Surge protection
level probe and Pt100 (optional): - integrated overvoltage protection acc. to EN 61000-4-5 (500 V symmetrical/1000 V asymmetrical) - overvoltage protection ≥ 1.0 kV, external if necessary temperature head transmitter (optional): provide overvoltage protection, externally if necessary
Input signal
level probe: change in capacitance Pt100 (optional): change in resistance temperature head transmitter (optional): Pt100 resistance signal, 4-wire
Measured variable
level probe: hydrostatic pressure of a liquid Pt100 (optional): temperature temperature head transmitter (optional): temperature
Measuring range
level probe: - predefined pressure measuring ranges in bar, see type code - customer-specific measuring ranges, factory-calibrated Pt100 (optional): temperature measurement from -10 ... 70 °C (+14 ... +158 °F)
Output signal
level probe: 4 ... 20 mA, 2-wire for hydrostatic pressure measured value Pt100 (optional): temperature-dependent resistance value temperature head transmitter (optional): 4 ... 20 mA Analog for temperature measured value, 2-wire
Signal range
3.8 ... 20.5 mA
Directive 2014/30/EU
EN 61326-1:2013 , EN 61326-2-3:2013
Directive 2014/35/EU
EN 61010-1:2010
Degree of protection
IEC 60529:2001
Resolution
current output: 1 µA
Reference operating conditions
level probe and Pt100 (optional): acc. to IEC 60770, T amb = constant in the range: +21 ... +33 °C (+70 ... +91 °F) temperature head transmitter (optional): calibration temperature 23 °C (+73 °F) ± 5 K
Long-term drift
level probe and Pt100 (optional): - ≤ 0.1 % of URL/year - ≤ 0.25 % of URL/5 years temperature head transmitter (optional): ≤ 0.1 K per year
Warm-up time
level probe: < 6 s Pt100 (optional): 20 m temperature head transmitter (optional): 4 s
Yanıt Süresi
level probe: 400 ms (T90 time), 500 ms (T99 time) Pt100 (optional): 160 s (T90 time), 300 s (T99 time)
Installation position
vertical from above
Medium temperature
level probe and Pt100 (optional): - Ø22 mm and Ø42 mm: -10 ... +70 °C (+14 ... +158 °F) - Ø29 mm: 0 ... +50 °C (+32 ... +122 °F) temperature head transmitter (optional): -40 ... +85 °C (-40 ... +185 °F) (= ambient temperature), install temperature head transmitter outside the medium.

Level probe hakkında

Level probe grubu, endüstriyel otomasyon uygulamalarında kullanılan bileşenleri kapsar. Stoğumuzda bu grupta 1 kalem ürün bulunmakta olup Pepperl+Fuchs markalarının ürünleri yer almaktadır. Ürün seçimi, uygulamanın çalışma koşulları ve mevcut sistemle uyumluluk dikkate alınarak yapılmalıdır.

Level probe grubundaki 1 ürünü gör

Seçim kriterleri

  • Uygulama koşulları

    Ortam sıcaklığı, nem, toz ve kimyasal maruziyet ürünün koruma sınıfını ve gövde malzemesini belirler. Bu bilgiler paylaşıldığında mühendislik ekibimiz uygun modeli eşleştirir.

  • Sistem uyumluluğu

    Mevcut kumanda sisteminin gerilim seviyesi, sinyal tipi ve haberleşme protokolü seçimi doğrudan etkiler. Değiştirilecek bir ürün varsa mevcut parça kodunun iletilmesi en hızlı yoldur.

LGC2 hakkında sık sorulanlar

Pepperl+Fuchs LGC2 nedir?
Pepperl+Fuchs LGC2, level probe grubunda yer alan bir endüstriyel otomasyon bileşenidir. Pepperl+Fuchs üretimi olan bu ürün yetkili kanal üzerinden tedarik edilmektedir.
LGC2 çalışma gerilimi nedir?
Pepperl+Fuchs LGC2 ürününün besleme gerilimi U r level probe and Pt100 (optional): - 10.5 ... 35 V DC (non-hazardous area) - 10.5 ... 30 V DC (hazardous area) temperature head transmitter (optional): 8 ... 35 V DC olarak belirtilmiştir. Bağlantı öncesinde mevcut kumanda devrenizin gerilim seviyesiyle uyumluluğunu doğrulamanız önerilir.
LGC2 çıkış tipi nedir?
Ürünün çıkış yapısı level probe: 4 ... 20 mA, 2-wire for hydrostatic pressure measured value Pt100 (optional): temperature-dependent resistance value temperature head transmitter (optional): 4 ... 20 mA Analog for temperature measured value, 2-wire şeklindedir. PLC giriş kartınızın PNP veya NPN beklediğini kontrol etmeniz gerekir; uyumsuz çıkış tipi sinyalin okunmamasına yol açar.
LGC2 fiyatı nedir?
Fiyat bilgisi kurumsal politikamız gereği yayınlanmamaktadır. LGC2 için güncel fiyat ve teslim süresini +90 533 461 51 10 numaralı hattımızdan veya teklif formu üzerinden öğrenebilirsiniz.
LGC2 stokta var mı?
Pepperl+Fuchs LGC2 için güncel stok durumu ve teslim süresi talebiniz üzerine teyit edilir. Adet ve teslim tarihi bilgisini +90 533 461 51 10 numaralı hattımızdan öğrenebilirsiniz.

Pepperl+Fuchs LGC2 için teklif alın

Adet bazlı fiyatlandırma, teslim süresi ve muadil ürün seçenekleri hakkında satış mühendislerimizden bilgi alabilirsiniz.

+90 533 461 51 10

Pepperl+Fuchs ailesinden

Tümünü gör →

Pepperl+Fuchs — komşu parça numaraları

WhatsApp’tan yazın